intelliSCAN IV 14 (preliminary specifications) | |||
Aperture | 14 mm | ||
Angle Transmitter of Galvanometer Scanners |
analog position detector | ||
Optical Configuration | |||
Wavelength range (standard) |
Standard coatings for all common laser systems: YAG- & fiber lasers, Green lasers, UV lasers, DUV lasers, CO2 lasers In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings |
||
Max. laser power (standard systems, 100% duty cycle) |
|||
Typical scan angle | ±0.35 rad (opt.) | ||
Image field size (1064 nm, f = 160 mm) |
|||
Fiber adapter | no | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Dynamic | |||
Number of installed tunings | |||
Typical tuning |
SCANahead, fast vector tuning |
||
Tracking error |
0 ms (SCANahead), 0.12 ms (fast vector tuning) |
||
Marking speed (f = 160 mm) |
|||
Positioning speed (f = 160 mm) |
|||
Writing speed (with F-Theta objective, f = 160 mm) |
|||
High writing quality |
1150 cps (SCANahead), 740 cps (fast vector tuning) |
||
Good writing quality |
940 cps (SCANahead), 510 cps (fast vector tuning) |
||
Step response (settling to 1/1000 of full scale) |
|||
1% of full scale | 0.33 ms | ||
10% of full scale | 1.08 ms | ||
Precision | |||
Repeatability (RMS) |
< 2 µrad | ||
Positioning resolution (max.)* |
20 bit * | ||
Nonlinearity | < 0.7 mrad / 44° | ||
Temperature drift | |||
Offset | < 15 µrad/K | ||
Gain | < 25 ppm/K | ||
8 hour drift (after 30 min warm-up) |
|||
Offset | < 100 µrad | ||
Gain | < 100 ppm | ||
24 hour drift (after 3 h warm-up) |
|||
Offset | < 100 µrad | ||
Gain | < 100 ppm | ||
* 20 bit: based on the full angle range (e.g. positioning resolution 0.7 µrad for angle range ±0.35 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
|
|||
Electrics / Control | |||
Servo control galvanometer scanner | digital servo control board | ||
Control interface (alternatives) |
digital SL2-100, digital XY2-100 Enhanced automatic recognition |
||
Advanced diagnosis options | yes (iDRIVE) | ||
Power requirements | 48 V DC, max. 5 A | ||
Mechanics | |||
Scan axes | 2-axis system | ||
Housing variants | standard: scan head | ||
Connector positions |
beam entrance side, alternatively opposite to beam exit side |
||
Dimensions (L x W x H) (standard housing) |
(165 x 118 x 156) mm3 with water cooling |
||
Weight without objective (standard housing) |
approx. 3.5 kg | ||
Beam displacement | 16.42 mm | ||
Other Provisions | |||
Water cooling | yes | ||
Air cooling | yes | ||
Options | objectives with optimized mounting kits | ||
Other Specifications | |||
Dimensions (L x W x H) (standard housing) |
(165 x 118 x 156) mm3 with water cooling |
||
Weight without objective (standard housing) |
approx. 3.5 kg | ||
Beam displacement | 16.42 mm | ||
Operating temperature | 25 °C ± 10 °C | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Skew | |||
Step response time (settling to 1/1000 of full scale) |
|||
Typical Optical Configurations | |||
Applications | |||
Typical Applications |
Photovoltaic production, Laser micromachining, Display production, Deep engraving, Drilling, Medical technology |
||