hurrySCAN 10 | |||
Aperture | 10 mm | ||
Angle Transmitter of Galvanometer Scanners |
analog position detector | ||
Optical Configuration | |||
Wavelength range (standard) |
Standard coatings for all common laser systems: YAG- & fiber lasers, Green lasers, UV lasers, DUV lasers, CO2 lasers In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings |
||
Max. laser power (standard systems, 100% duty cycle) |
200 W @ 1064 nm | ||
Typical scan angle | ±0.35 rad (mech.) | ||
Image field size (1064 nm, f = 160 mm) |
120 mm x 120 mm (for f = 163 mm) |
||
Fiber adapter | no | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Dynamic | |||
Number of installed tunings | 1 | ||
Typical tuning | fast vector tuning | ||
Tracking error | 0.18 ms | ||
Marking speed (f = 160 mm) |
2.0 m/s | ||
Positioning speed (f = 160 mm) |
7.0 m/s | ||
Writing speed (with F-Theta objective, f = 160 mm) |
|||
High writing quality | 400 cps | ||
Good writing quality | 640 cps | ||
Step response (settling to 1/1000 of full scale) |
|||
1% of full scale | 0.35 ms | ||
10% of full scale | 0.90 ms | ||
Precision | |||
Repeatability (RMS) |
< 2 µrad | ||
Positioning resolution (max.)* |
18 bit * | ||
Nonlinearity | < 3.5 mrad / 44° | ||
Temperature drift | |||
Offset | |||
Gain | |||
8 hour drift (after 30 min warm-up) |
|||
Offset | |||
Gain | |||
24 hour drift (after 3 h warm-up) |
|||
Offset | |||
Gain | |||
* 18 bit: based on the full angle range (e.g. positioning resolution 2.8 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
|
|||
Electrics / Control | |||
Servo control galvanometer scanner | analog servo control board | ||
Control interface (alternatives) |
digital SL2-100, digital XY2-100 standard, analog ±4.8 V, analog ±9.6 V |
||
Advanced diagnosis options | no | ||
Power requirements | ±(15+1.5) V DC, max. 3 A | ||
Mechanics | |||
Scan axes | 2-axis system | ||
Housing variants |
standard: scan head alternative: module (without housing) |
||
Connector positions |
beam entrance side, alternatively opposite to beam exit side |
||
Dimensions (L x W x H) (standard housing) |
(175 x 114 x 147) mm3 | ||
Weight without objective (standard housing) |
approx. 3 kg | ||
Beam displacement | 12.56 mm | ||
Other Provisions | |||
Water cooling | optionally | ||
Air cooling | optionally | ||
Options | objectives with optimized mounting kits | ||
Other Specifications | |||
Dimensions (L x W x H) (standard housing) |
(175 x 114 x 147) mm3 | ||
Weight without objective (standard housing) |
approx. 3 kg | ||
Beam displacement | 12.56 mm | ||
Operating temperature | |||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Skew | < 1.5 mrad | ||
Step response time (settling to 1/1000 of full scale) |
|||
Typical Optical Configurations | |||
Applications | |||
Typical Applications |
Materials processing, Marking, Microstructuring, Rapid Manufacturing, 3D applications, Processing-on-the-fly |
||