Standard Series

intelliSCAN 30

Print
Aperture
30 mm
Angle Transmitter of Galvanometer Scanners
analog position detector
Show Optical Configuration
Wavelength range
(standard)
Standard coatings for all common laser systems:
YAG- & fiber lasers,
Green lasers,
UV lasers,
CO2 lasers

In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings
Max. laser power
(standard systems, 100% duty cycle)
5000 W @ 1064 nm
with air cooling
Typical scan angle
±0.35 rad (opt.)
Image field size
(1064 nm, f = 160 mm)
30 mm x 30 mm
Typical spot size
(1064 nm, f = 160 mm, M2 = 1.0)
11 µm
Show Dynamics
Number of installed tunings
up to 3
Typical tuning
fast vector tuning
Tracking error
0.55 ms
Marking speed
(f = 160 mm)
0.7 m/s
Positioning speed
(f = 160 mm)
9.0 m/s
Writing speed
(with F-Theta lens, f = 160 mm)
High writing quality
150 cps
Good writing quality
220 cps
Step response time
(settling to 1/1000 of full scale)
1% of full scale
1.1 ms
10% of full scale
2.5 ms
Precision
Repeatability
(RMS)
< 2 µrad
Positioning resolution
(max.)*
18 bit *
Nonlinearity
< 3.5 mrad / 44°
* 18 bit: based on the full angle range (e.g. positioning resolution 2.8 µrad for angle range ±0.36 rad),
resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
Electronics / Control
Servo control galvanometer scanner
digital servo control board
Control interface
(alternatives)
digital SL2-100,
digital XY2-100 Enhanced
Advanced diagnosis options
yes (iDRIVE)
Power requirements
30 V DC, max. 6 A
Mechanics
Scan axes
2-axis system
Housing variants
standard: scan head
alternative: module (without housing)
Connector positions
beam entrance side
Weight without objective
(standard housing)
5.8 kg
Dimensions (L x W x H)
(standard housing)
(206.9 x 140 x 180) mm3
Beam displacement
35.53 mm
Other Provisions
Water cooling
yes
Air cooling
yes
Other Specifications
Operating temperature
25 °C ± 10 °C
Gain error
< 5 mrad
Zero offset deviation
< 5 mrad
Add-ons
Combinable with varioSCAN for 3D applications,
control with SCANLAB´s RTC boards,
camera adapter
Typical Applications
Micromachining,
Marking, welding, drilling,
Rapid prototyping,
Rapid tooling,
Photovoltaic production,
Processing-on-the-fly
Compare Products
Application-Micromachining-Products

Add-Ons

Options

  • Objectives with optimized mounting kits
  • Light weight mirrors
  • Application- and customer-specific tunings

Applications

More Questions?

Get in touch!

Phone +49 89 800 746-0