SCANcube 10 | |||
Aperture | 10 mm | ||
Angle Transmitter of Galvanometer Scanners |
analog position detector | ||
Optical Configuration | |||
Wavelength range (standard) |
Standard coatings for all common laser systems: YAG- & fiber lasers, Green lasers, UV lasers, CO2 lasers In addition, our portfolio includes numerous multiple wavelength and broadband coatings |
||
Max. laser power (standard systems, 100% duty cycle) |
200 W @ 1064 nm | ||
Typical scan angle | ±0.35 rad (opt.) | ||
Image field size (1064 nm, f = 160 mm) |
110 mm x 110 mm | ||
Fiber adapter | no | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Dynamic | |||
Number of installed tunings | 1 | ||
Typical tuning | fast vector tuning | ||
Tracking error | 0.16 ms | ||
Marking speed (f = 160 mm) |
2.0 m/s | ||
Positioning speed (f = 160 mm) |
10.0 m/s | ||
Writing speed (with F-Theta objective, f = 160 mm) |
|||
High writing quality | 400 cps | ||
Good writing quality | 640 cps | ||
Step response (settling to 1/1000 of full scale) |
|||
1% of full scale | 0.40 ms | ||
10% of full scale | 1.2 ms | ||
Precision | |||
Repeatability (RMS) |
< 2 µrad | ||
Positioning resolution (max.)* |
16 bit * | ||
Nonlinearity | < 3.5 mrad / 44° | ||
Temperature drift | |||
Offset | < 30 µrad/K | ||
Gain | < 80 ppm/K | ||
8 hour drift (after 30 min warm-up) |
|||
Offset | |||
Gain | |||
24 hour drift (after 3 h warm-up) |
|||
Offset | |||
Gain | |||
* 16 bit: based on the full angle range (e.g. positioning resolution 11 µrad for angle range ±0.36 rad)
|
|||
Electrics / Control | |||
Servo control galvanometer scanner | analog servo control board | ||
Control interface (alternatives) |
digital SL2-100, digital XY2-100 standard, analog ±4.8 V |
||
Advanced diagnosis options | no | ||
Power requirements | ±15 V DC, max. 2 A each | ||
Mechanics | |||
Scan axes | 2-axis system | ||
Housing variants | standard: scan head | ||
Connector positions | beam entrance side | ||
Dimensions (L x W x H) (standard housing) |
(114 x 96.5 x 94) mm3 | ||
Weight without objective (standard housing) |
1.9 kg | ||
Beam displacement | 12.54 mm | ||
Other Provisions | |||
Water cooling | no | ||
Air cooling | no | ||
Options | objectives with optimized mounting kits | ||
Other Specifications | |||
Dimensions (L x W x H) (standard housing) |
(114 x 96.5 x 94) mm3 | ||
Weight without objective (standard housing) |
1.9 kg | ||
Beam displacement | 12.54 mm | ||
Operating temperature | 25 °C ± 10 °C | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Skew | |||
Step response time (settling to 1/1000 of full scale) |
|||
Typical Optical Configurations | |||
Applications | |||
Typical Applications |
Marking and coding, Semiconductor and electronics industry, Processing-on-the-fly |
||