intelliSCANde 20 | |||
Aperture | 20 mm | ||
Angle Transmitter of Galvanometer Scanners |
digital encoder | ||
Optical Configuration | |||
Wavelength range (standard) |
Standard coatings for all common laser systems: YAG- & fiber lasers, Green lasers, UV lasers, CO2 lasers In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings |
||
Max. laser power (standard systems, 100% duty cycle) |
2000 W @ 1064 nm with air cooling |
||
Typical scan angle | ±0.35 rad (opt.) | ||
Image field size (1064 nm, f = 160 mm) |
60 mm x 60 mm | ||
Fiber adapter | no | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Dynamic | |||
Number of installed tunings | up to 3 | ||
Typical tuning | fast vector tuning | ||
Tracking error | 0.32 ms | ||
Marking speed (f = 160 mm) |
1.0 m/s | ||
Positioning speed (f = 160 mm) |
11.0 m/s | ||
Writing speed (with F-Theta objective, f = 160 mm) |
|||
High writing quality | 230 cps | ||
Good writing quality | 340 cps | ||
Step response (settling to 1/1000 of full scale) |
|||
1% of full scale | 0.70 ms | ||
10% of full scale | 1,9 ms | ||
Precision | |||
Repeatability (RMS) |
< 0.4 µrad | ||
Positioning resolution (max.)* |
20 bit * | ||
Nonlinearity | < 0.5 mrad / 44° | ||
Temperature drift | |||
Offset | < 15 µrad/K | ||
Gain | < 8 ppm/K | ||
8 hour drift (after 30 min warm-up) |
|||
Offset | < 20 µrad | ||
Gain | < 20 ppm | ||
24 hour drift (after 3 h warm-up) |
|||
Offset | < 20 µrad | ||
Gain | < 25 ppm | ||
* 20 bit: based on the full angle range (e.g. positioning resolution 0.7 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
|
|||
Electrics / Control | |||
Servo control galvanometer scanner | digital servo control board | ||
Control interface (alternatives) |
digital SL2-100, digital XY2-100 Enhanced |
||
Advanced diagnosis options | yes (iDRIVE) | ||
Power requirements |
Available variants: 30 V DC, max. 3 A 48 V DC, max. 3 A |
||
Mechanics | |||
Scan axes | 2-axis system | ||
Housing variants | standard: scan head | ||
Connector positions | beam entrance side | ||
Dimensions (L x W x H) (standard housing) |
(206.9 x 140 x 180) mm3 | ||
Weight without objective (standard housing) |
5.8 kg | ||
Beam displacement | 25.25 mm | ||
Other Provisions | |||
Water cooling | yes | ||
Air cooling | yes | ||
Options |
objectives with optimized mounting kits, light weight mirrors, application- and customer-specific tunings |
||
Other Specifications | |||
Dimensions (L x W x H) (standard housing) |
(206.9 x 140 x 180) mm3 | ||
Weight without objective (standard housing) |
5.8 kg | ||
Beam displacement | 25.25 mm | ||
Operating temperature | 25 °C ± 10 °C | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Skew | |||
Step response time (settling to 1/1000 of full scale) |
|||
Typical Optical Configurations | |||
Applications | |||
Typical Applications |
Micromachining, Marking, welding, drilling, Rapid prototyping, Rapid tooling, Photovoltaic production, Processing-on-the-fly |
||