intelliSCANse 14 | |||
Aperture | 14 mm | ||
Angle Transmitter of Galvanometer Scanners |
digital encoder | ||
Optical Configuration | |||
Wavelength range (standard) |
Standard coatings for all common laser systems: YAG- & fiber lasers, Green lasers, UV lasers, DUV lasers, CO2 lasers In addition, our portfolio includes numerous multiple wavelength and broadband coatings, as well as coatings for short-pulse applications and polarization-maintaining coatings |
||
Max. laser power (standard systems, 100% duty cycle) |
440 W @ 1064 nm | ||
Typical scan angle | ±0.35 rad (opt.) | ||
Image field size (1064 nm, f = 160 mm) |
95 mm x 95 mm | ||
Fiber adapter | no | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Dynamic | |||
Number of installed tunings | up to 3 | ||
Typical tuning | sharp edge tuning | ||
Tracking error | 0.15 ms | ||
Marking speed (f = 160 mm) |
2.0 m/s | ||
Positioning speed (f = 160 mm) |
5.0 m/s | ||
Writing speed (with F-Theta objective, f = 160 mm) |
|||
High writing quality | 480 cps | ||
Good writing quality | 680 cps | ||
Step response (settling to 1/1000 of full scale) |
|||
1% of full scale | 0.45 ms | ||
10% of full scale | 3.0 ms | ||
Precision | |||
Repeatability (RMS) |
< 0.4 µrad | ||
Positioning resolution (max.)* |
20 bit * | ||
Nonlinearity | < 0.5 mrad / 44° | ||
Temperature drift | |||
Offset | < 15 µrad/K | ||
Gain | < 8 ppm/K | ||
8 hour drift (after 30 min warm-up) |
|||
Offset | < 20 µrad | ||
Gain | < 20 ppm | ||
24 hour drift (after 3 h warm-up) |
|||
Offset | < 20 µrad | ||
Gain | < 25 ppm | ||
* 20 bit: based on the full angle range (e.g. positioning resolution 0.7 µrad for angle range ±0.36 rad), <br /> resolutions better than 16 bit (11 µrad) only together with SL2-100 interface
|
|||
Electrics / Control | |||
Servo control galvanometer scanner | digital servo control board | ||
Control interface (alternatives) |
digital SL2-100, digital XY2-100 Enhanced |
||
Advanced diagnosis options | yes (iDRIVE) | ||
Power requirements |
Available variants: 30 V DC, max. 3 A 48 V DC, max. 3 A |
||
Mechanics | |||
Scan axes | 2-axis system | ||
Housing variants | standard: scan head | ||
Connector positions |
beam entrance side, alternatively opposite to beam exit side |
||
Dimensions (L x W x H) (standard housing) |
(175 x 114 x 147) mm3 | ||
Weight without objective (standard housing) |
3 kg | ||
Beam displacement | 16.42 mm | ||
Other Provisions | |||
Water cooling | optionally | ||
Air cooling | optionally | ||
Options |
objectives with optimized mounting kits, light weight mirrors, application- and customer-specific tunings |
||
Other Specifications | |||
Dimensions (L x W x H) (standard housing) |
(175 x 114 x 147) mm3 | ||
Weight without objective (standard housing) |
3 kg | ||
Beam displacement | 16.42 mm | ||
Operating temperature | 25 °C ± 10 °C | ||
Gain error | < 5 mrad | ||
Zero offset deviation | < 5 mrad | ||
Skew | |||
Step response time (settling to 1/1000 of full scale) |
|||
Typical Optical Configurations | |||
Applications | |||
Typical Applications |
Microprocessing, Microstructuring, Materials processing, Processing-on-the-fly |
||