Standard series

Standard Scan Head With Improved Dynamics

The basiCube 10d is approx. 10% faster than the basiCube 10. As options for power supply, 24 V or 30 V are available. It is only slightly higher than the basiCube 10 and facilitates very straight forward integration into production lines.

basiCube 10d is available for four different wavelengths (355 nm, 532 nm, 1064 nm or 10600 nm) and is combinable with a variety of objectives. Control is via the digital XY2-100 or the SL2-100 protocol.

basiCube 10d

Print
Aperture
10 mm
Angle Transmitter of Galvanometer Scanners
analog position detector
Show Optical Configuration
Wavelength range
(standard)
Available standard coatings:
1064 nm
532 nm
355 nm
10600 nm
Max. laser power
(standard systems, 100% duty cycle)
150 W @ 1064 nm
Typical scan angle
±0.35 rad (opt.)
Image field size
(1064 nm, f = 160 mm)
110 mm x 110 mm
Typical spot size
(1064 nm, f = 160 mm, M2 = 1.0)
32 µm
Show Dynamics
Number of installed tunings
1
Typical tuning
fast vector tuning
Tracking error
0.10 ms *
Marking speed
(f = 160 mm)
3.0 m/s
Positioning speed
(f = 160 mm)
20.8 m/s
Writing speed
(with F-Theta lens, f = 160 mm)
High writing quality
590 cps
Good writing quality
860 cps
Step response time
(settling to 1/1000 of full scale)
1% of full scale
0.30 ms
10% of full scale
0.9 ms
* dynamically relevant tracking error
Precision
Repeatability
(RMS)
< 2 µrad
Positioning resolution
(max.)*
16 Bit *
Nonlinearity
< 0.9 mrad / 44°
Temperature drift
Offset
< 30 µrad/K
Gain
< 160 ppm/K
8-h-drift
(after 30 min warm-up)
Offset
< 100 µrad
Gain
< 250 ppm
* 16 bit: based on the full angle range (e.g. positioning resolution 11 µrad for angle range ±0.36 rad)
Electronics / Control
Servo control galvanometer scanner
digital servo control board
Control interface
(alternatives)
digital SL2-100,
digital XY2-100 standard
Advanced diagnosis options
no
Power requirements
Available variants:
24 V DC, max. 3 A
30 V DC, max. 3 A
Mechanics
Scan axes
2-axis system
Housing variants
standard: scan head
Connector positions
beam entrance side
Dimensions (L x W x H)
(standard housing)
(105.6 x 91.4 x 91.3) mm3
Beam displacement
12.54 mm
Other Provisions
Water cooling
no
Air cooling
no
Other Specifications
Operating temperature
25 °C ± 10 °C
Gain error
< 5 mrad
Zero offset deviation
< 5 mrad
Add-ons
Combinable with varioSCAN for 3D applications,
control with SCANLAB´s RTC boards,
camera adapter
Typical Applications
Marking,
Coding,
Processing-on-the-fly
Compare Products