Standard Series

The Standard Scan Head for Laser Labeling

The basiCube 10's full 10 mm aperture is ideal for use with fiber lasers. Its ultra-compact housing facilitates very straight forward integration into production lines. And it offers impressive dynamics , e.g. 800 cps with good writing quality.

basiCube 10 is available for four different wavelengths (355 nm, 532 nm, 1064 nm or 10600 nm) and is combinable with a variety of objectives. Control is via the digital XY2-100 or the SL2-100 protocol.

basiCube 10

Print
Aperture
10 mm
Angle Transmitter of Galvanometer Scanners
analog position detector
Show Optical Configuration
Wavelength range
(standard)
Available standard coatings:
1064 nm
532 nm
355 nm
10600 nm
Max. laser power
(standard systems, 100% duty cycle)
150 W @ 1064 nm
Typical scan angle
±0.35 rad (opt.)
Image field size
(1064 nm, f = 160 mm)
110 mm x 110 mm
Typical spot size
(1064 nm, f = 160 mm, M2 = 1.0)
32 µm
Show Dynamics
Number of installed tunings
1
Typical tuning
fast vector tuning
Tracking error
0.14 ms
Marking speed
(f = 160 mm)
2.5 m/s
Positioning speed
(f = 160 mm)
12.8 m/s
Writing speed
(with F-Theta lens, f = 160 mm)
High writing quality
570 cps
Good writing quality
800 cps
Step response time
(settling to 1/1000 of full scale)
1% of full scale
0.35 ms
10% of full scale
1.0 ms
Precision
Repeatability
(RMS)
< 2 µrad
Positioning resolution
(max.)*
16 bit *
Nonlinearity
< 3.5 mrad / 44°
Temperature drift
Offset
< 30 µrad/K
Gain
< 160 ppm/K
8-h-drift
(after 30 min warm-up)
Offset
< 100 µrad
Gain
< 250 ppm
* 16 bit: based on the full angle range (e.g. positioning resolution 11 µrad for angle range ±0.36 rad)
Electronics / Control
Servo control galvanometer scanner
analog servo control board
Control interface
(alternatives)
digital SL2-100,
digital XY2-100 standard
Advanced diagnosis options
no
Power requirements
±15 V DC, max. 3 A each
Mechanics
Scan axes
2-axis system
Housing variants
standard: scan head
Connector positions
beam entrance side
Weight without objective
(standard housing)
1.5 kg
Dimensions (L x W x H)
(standard housing)
(105.6 x 91.4 x 90.5) mm3
Beam displacement
12.54 mm
Other Provisions
Water cooling
no
Air cooling
no
Other Specifications
Operating temperature
25 °C ± 10 °C
Gain error
< 5 mrad
Zero offset deviation
< 5 mrad
Add-ons
Combinable with varioSCAN for 3D applications,
control with SCANLAB´s RTC boards,
camera adapter
Typical Applications
Marking,
Coding,
Processing-on-the-fly
Compare Products
Application-Micromachining-Products

Add-Ons

Options

  • Objectives with optimized mounting kits

Applications

More Questions?

Get in touch!

Phone +49 89 800 746-0