Standard Series

Compact Scan Head for Laser Marking

The basiCube 14's full 14 mm aperture is ideal for use with fiber lasers. Its ultra-compact housing facilitates very straightforward integration into production lines. Its 24 V or 30 V power supply eases integration into laser processing machines further. It offers impressive dynamics, e.g. 600 cps with good writing quality.

basiCube 14 is available for three different wavelengths (355 nm, 1064 nm or 10600 nm) and is combinable with a variety of objectives. Control is via the digital XY2-100 or the SL2-100 protocol.

basiCube 14

Print
Aperture
14 mm
Angle Transmitter of Galvanometer Scanners
analog position detector
Show Optical Configuration
Wavelength range
(standard)
Available standard coatings:
1064 nm
355 nm
10600 nm
Max. laser power
(standard systems, 100% duty cycle)
250 W @ 1064 nm
Typical scan angle
±0.35 rad (opt.)
Image field size
(1064 nm, f = 160 mm)
95 mm x 95 mm
Typical spot size
(1064 nm, f = 160 mm, M2 = 1.0)
23 µm
Show Dynamics
Number of installed tunings
1
Typical tuning
fast vector tuning
Tracking error
0.18 ms
Marking speed
(f = 160 mm)
2.0 m/s
Positioning speed
(f = 160 mm)
12.8 m/s
Writing speed
(with F-Theta lens, f = 160 mm)
High writing quality
375 cps
Good writing quality
600 cps
Step response time
(settling to 1/1000 of full scale)
1% of full scale
0.45 ms
10% of full scale
1.4 ms
Precision
Repeatability
(RMS)
< 2 µrad
Positioning resolution
(max.)*
16 Bit *
Nonlinearity
< 0.9 mrad / 44°
Temperature drift
Offset
< 30 µrad/K
Gain
< 160 ppm/K
8-h-drift
(after 30 min warm-up)
Offset
< 100 µrad
Gain
< 250 ppm
* 16 bit: based on the full angle range (e.g. positioning resolution 11 µrad for angle range ±0.36 rad)
Electronics / Control
Servo control galvanometer scanner
digital servo control board
Control interface
(alternatives)
digital SL2-100,
digital XY2-100 standard
Advanced diagnosis options
no
Power requirements
Available variants:
24 V DC, max. 3 A
30 V DC, max. 3 A
Mechanics
Scan axes
2-axis system
Housing variants
standard: scan head
Connector positions
beam entrance side
Weight without objective
(standard housing)
2.15 kg
Dimensions (L x W x H)
(standard housing)
(123 x 95 x 104) mm3
Beam displacement
16.42 mm
Other Provisions
Water cooling
no
Air cooling
no
Other Specifications
Operating temperature
25 °C ± 10 °C
Gain error
< 5 mrad
Zero offset deviation
< 5 mrad
Add-ons
Combinable with varioSCAN for 3D applications,
control with SCANLAB´s RTC boards,
camera adapter
Typical Applications
Marking,
Coding,
Processing-on-the-fly
Compare Products
Application-Micromachining-Products

Add-Ons

Options

  • Objectives with optimized mounting kits

Applications

More Questions?

Get in touch!